[Home ] [Archive]    
:: Volume 23, Issue 9 (12-2021) ::
J Mil Med 2021, 23(9): 693-701 Back to browse issues page
Design of Dual-Purpose Treadmill and Gait Simulator Device for Veterans and Disabled People
Mohammad Moein, Amin Amini *, Ahmadreza Yosefpor
Department of Knowledge and Cognitive Intelligence, Imam Hossein University, Tehran, Iran , aminamini@ihu.ac.ir
Abstract:   (301 Views)
Background and Aim: The purpose of this study was to design of dual-purpose treadmill and gait simulator device for veterans and disabled people. This device can be used by both healthy and stroke patients, spinal cord injury, Parkinson's disease, MS and people who have lost their ability to walk for a temporary period.
Methods: The device design is such that the protective waistcoat has sensors to determine the amount of stress applied to the parts where the supporting rope is attached to the waistcoat. The amount of pressure displayed along with other information is displayed on the screen embedded in the device so that the therapist is aware of the information while practicing.
Results: The treadmill is also designed in two ways, which can be adjusted automatically to allow the individual to move at their desired speed, as well as to be able to manually move the treadmill by applying pressure through the legs.
Conclusion: This treadmill causes of strengthens the muscles of people with disabilities who have lost their ability to walk for a while and, in addition, their muscles have weakened. Also, the protective waistcoat has a pressure sensor that can be adjusted based on body weight.
Keywords: Treadmill, Sensor, Gait Simulator, Muscles
Full-Text [PDF 839 kb]   (80 Downloads)    
Type of Study: Orginal Research | Subject: military medcine
Received: 2020/03/24 | Accepted: 2021/11/24 | Published: 2021/12/10
Send email to the article author



XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moein M, Amini A, Yosefpor A. Design of Dual-Purpose Treadmill and Gait Simulator Device for Veterans and Disabled People. J Mil Med. 2021; 23 (9) :693-701
URL: http://militarymedj.ir/article-1-2453-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 23, Issue 9 (12-2021) Back to browse issues page
مجله طب‌نظامی Journal Mil Med
Persian site map - English site map - Created in 0.05 seconds with 29 queries by YEKTAWEB 4372